SubjectRe: [PATCH] iio: kx022a: Fix acceleration value scaling
On Fri, Oct 20, 2023 at 5:39 PM Matti Vaittinen
<mazziesaccount@gmail.com> wrote:
>
> On 10/19/23 21:21, Jagath Jog J wrote:
> > Hi Matti,
> >
> > On Thu, Oct 19, 2023 at 6:54 PM Matti Vaittinen
> > <mazziesaccount@gmail.com> wrote:
> >>

> >> I did only very quick testing on KX022A and iio_generic_buffer. After
> >> the patch the values seemed to be correct order of magnitude. Further
> >> testing is appreciated :)
> >
> > Values are correct with this change, Thank you for fixing.
> > Tested-by: Jagath Jog J <jagathjog1996@gmail.com>
>
> Thanks a ton for testing! May I ask which component did you use (or did
> you just use some 'simulated' regster values?)

Hi Matti,

I just simulated with the register values, Should the 'tested-by' tag only be
provided after hardware testing? I referred to this driver because it's
the most recent accelerometer driver that was merged.

Regards
Jagath

\
 
 \ /