Messages in this thread | | | Date | Thu, 12 Oct 2023 08:58:04 +0100 | From | Jonathan Cameron <> | Subject | Re: [PATCH v5 1/4] staging: iio: resolver: ad2s1210: refactor sample toggle |
| |
On Tue, 10 Oct 2023 16:12:33 -0500 David Lechner <dlechner@baylibre.com> wrote:
> This refactors the sample line toggle in the ad2s1210 resolver driver > to a separate function. The sample has some timing requirements, so > this ensures that it is always done the same way, both in the existing > call sites and any future usage. > > Previously, the sample line was kept on for the duration of the read, > but this is not necessary. Data is latched in on the rising edge and > after the specified delay the state of the sample line does not matter. > > Signed-off-by: David Lechner <dlechner@baylibre.com> Applied.
| |