Messages in this thread | | | Date | Thu, 26 Jan 2023 22:03:10 +0000 | From | Cristian Marussi <> | Subject | Re: [PATCH] regulator: scmi: Allow for zero voltage domains |
| |
On Thu, Jan 26, 2023 at 06:38:20PM +0000, Mark Brown wrote: > On Thu, Jan 26, 2023 at 06:05:11PM +0000, Cristian Marussi wrote: > > SCMI Voltage protocol allows the platform to report no voltage domains > > on discovery, while warning the user about such an odd configuration. > > This patch removes all diagnostics in this case?
You'll still see a warning from the SCMI core Voltage Protocol saying:
"No Voltage domains found."
but nothing from the regulator driver itself which will successfully probe, albeit not creating any regulators...if this is what you mean.
Thanks for having a look, Cristian
| |