Messages in this thread | | | Date | Fri, 20 Jan 2023 17:17:05 +0200 | From | Andy Shevchenko <> | Subject | Re: [PATCH 2/3] Input: ads7846 - always set last command to PWRDOWN |
| |
On Fri, Jan 20, 2023 at 01:45:43PM +0100, Luca Ellero wrote: > Controllers that report pressure (e.g. ADS7846) use 5 commands and the > correct sequence is READ_X, READ_Y, READ_Z1, READ_Z2, PWRDOWN. > > Controllers that don't report pressure (e.g. ADS7845/ADS7843) use only 3 > commands and the correct sequence should be READ_X, READ_Y, PWRDOWN. But > the sequence sent was incorrect: READ_X, READ_Y, READ_Z1. > > Fix this by setting the third (and last) command to PWRDOWN.
Provide a Fixes: tag?
> Signed-off-by: Luca Ellero <l.ellero@asem.it>
-- With Best Regards, Andy Shevchenko
| |