Messages in this thread |  | | Date | Sun, 15 Jan 2023 15:35:23 +0100 | Subject | Re: [PATCH] dt-bindings: clock: qcom,a53pll: drop operating-points-v2 | From | Krzysztof Kozlowski <> |
| |
On 13/01/2023 21:28, Stephen Boyd wrote: > Quoting Krzysztof Kozlowski (2023-01-13 06:58:59) >> The CPU PLL clock node does not use OPP tables (neither driver). > > What device is qcom_a53pll_get_freq_tbl() operating on?
On its own, internal table. While of course driver could be converted to operating-points-v2, no one did it within last 5 years, so why it should happen now?
Best regards, Krzysztof
|  |