Messages in this thread | ![/](/images/icornerl.gif) | | Date | Tue, 10 Jan 2023 10:20:24 +0100 | Subject | Re: [PATCH v2 2/3] drm/panel: boe-tv101wum-nl6: Reduce lcm_reset to send initial code time | From | AngeloGioacchino Del Regno <> |
| |
Il 10/01/23 06:54, xinlei.lee@mediatek.com ha scritto: > From: Xinlei Lee <xinlei.lee@mediatek.com> > > Since the panel spec stipulates that the time from lcm_reset to DSI to > send the initial code should be greater than 6ms and less than 40ms, > so reduce the delay before sending the initial code and avoid panel > exceptions.
Please change the commit title to describe what you're doing.
drm/panel: boe-tv101wum-nl6: Remove extra delay in init commands
....and the commit description should also contain something like
Reduce the delay after LCM reset by removing an extra delay in the initialization commands array. The required delay of at least 6ms after reset is guaranteed by boe_panel_prepare().
Regards, Angelo