Messages in this thread Patch in this message | | | From | John Garry <> | Subject | [PATCH v2 3/5] bus: hisi_lpc: Correct error code for timeout | Date | Fri, 2 Sep 2022 15:47:19 +0800 |
| |
From: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
The usual error code is -ETIMEDOUT, the currently used -ETIME is specific for timers.
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Reviewed-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com> Signed-off-by: John Garry <john.garry@huawei.com> --- drivers/bus/hisi_lpc.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/bus/hisi_lpc.c b/drivers/bus/hisi_lpc.c index 03d4d96ff794..a6513a571d7b 100644 --- a/drivers/bus/hisi_lpc.c +++ b/drivers/bus/hisi_lpc.c @@ -85,7 +85,7 @@ static int wait_lpc_idle(void __iomem *mbase, unsigned int waitcnt) ndelay(LPC_NSEC_PERWAIT); } while (--waitcnt); - return -ETIME; + return -ETIMEDOUT; } /* -- 2.35.3
| |