SubjectRe: [PATCH 2/3] iio: temperature: mlx90632 Read sampling frequency
On Fri, Sep 2, 2022 at 4:13 PM <cmo@melexis.com> wrote:
>
> From: Crt Mori <cmo@melexis.com>
>
> Allow user to read sensor sampling frequency to better plan the

the user
...or...
users

> application measurement requests.

...

> + int ret;
> + unsigned int meas1;

Reversed xmas tree order?

...

> +static const int mlx90632_freqs[8][2] = { {0, 500000}, {1, 0}, {2, 0}, {4, 0},
> + {8, 0}, {16, 0}, {32, 0}, {64, 0} };

Can we use better indentation? Also one of the sizes in the definition
can be dropped.

--
With Best Regards,
Andy Shevchenko

\
 
 \ /