Messages in this thread | | | Date | Tue, 9 Aug 2022 14:31:27 +0300 | Subject | Re: [PATCH 1/2] dt-bindings: hwmon: sparx5: use correct clock | From | Krzysztof Kozlowski <> |
| |
On 09/08/2022 14:22, Robert Marko wrote: > SparX-5 temperature sensor uses system reference clock and not the AHB bus > clock as indicated by the register information [1]. > > So, correct the clock description as well the included example. > > [1] https://microchip-ung.github.io/sparx-5_reginfo/reginfo_sparx-5.html?select=hsiowrap,temp_sensor,temp_sensor_cfg,clk_cycles_1us >
Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Best regards, Krzysztof
| |