Patch in this message
/
From
Subject[PATCH 2/2] arm64: dts: microchip: sparx5: use correct clock for tmon
Date
SparX-5 temperature sensor uses system reference clock and not the AHB bus
clock as indicated by the register information [1].

Configured number of system clock cycles in one 1us is now almost spot on
to the default register value.

[1] https://microchip-ung.github.io/sparx-5_reginfo/reginfo_sparx-5.html?select=hsiowrap,temp_sensor,temp_sensor_cfg,clk_cycles_1us

Fixes: d14f6a1ae07f ("arm64: dts: sparx5: Add hwmon temperature sensor")
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
---
arch/arm64/boot/dts/microchip/sparx5.dtsi | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/arch/arm64/boot/dts/microchip/sparx5.dtsi b/arch/arm64/boot/dts/microchip/sparx5.dtsi
index 6f6aab48516e..c9367127670b 100644
--- a/arch/arm64/boot/dts/microchip/sparx5.dtsi
+++ b/arch/arm64/boot/dts/microchip/sparx5.dtsi
@@ -421,7 +421,7 @@ tmon0: tmon@610508110 {
compatible = "microchip,sparx5-temp";
reg = <0x6 0x10508110 0xc>;
#thermal-sensor-cells = <0>;
- clocks = <&ahb_clk>;
+ clocks = <&sys_clk>;
};

mdio0: mdio@6110102b0 {
--
2.37.1
\
 
 \ /