Subject[PATCH v2 0/2] iio: temperature: mlx90632: Add supply regulator
Date
Add supply regulator to the sensor as initial update before proper power
management is presented. This will reduce the diff for the following
patches.

Changes in v2:

- Regulator voltage was removed as per comments from Jonathan Cameron
and Lars-Peter Clausen
- Style handling for the error reporting of the regulator DT binding
was adjusted
- NEW: Delay function was created and grouped together with call from
the reset command, to ensure consistency and reduce the amount of
code.

Crt Mori (2):
iio: temperature: mlx90632 Add supply regulator to sensor
dt-bindings: iio: mlx90632 Add supply regulator documentation

.../iio/temperature/melexis,mlx90632.yaml | 4 ++
drivers/iio/temperature/mlx90632.c | 63 +++++++++++++++++--
2 files changed, 62 insertions(+), 5 deletions(-)

--