    SubjectRe: [PATCH v3 13/19] hwmon: (mr75203) modify the temperature equation according to series 5 datasheet
    On Tue, Aug 30, 2022 at 07:22:06PM +0000, Eliav Farber wrote:
    > Modify the equation and coefficients used to convert the digital output
    > to temperature according to series 5 of the Moortec Embedded Temperature
    > Sensor (METS) datasheet:
    > T = G + H * (n / cal5 - 0.5) + J * F
    >
    > Where:
    > *) G = 60, H = 200, cal5 = 4094, J = -0.1.
    > *) F = frequency clock in MHz.
    > *) n is the digital output.
    >
    > In code, the G, H and J coefficients are multiplied by a factor of 1000
    > to get the temperature in milli-Celsius.
    > Final result is clamped in case it exceeds min/max thresholds.
    >
    > Change is done since it is not clear where the current equation and

    not clear -> unclear

    > coefficients came from.

    ...

    > +#define PVT_TEMP_MIN -40000
    > +#define PVT_TEMP_MAX 125000

    Unit suffix? _mC perhaps would be enough.

    --
    With Best Regards,
    Andy Shevchenko


    \
     
     \ /