Messages in this thread Patch in this message | | | From | Eliav Farber <> | Subject | [PATCH 09/16] hwmon: (mr75203) add VM pre-scalar property for Moortec PVT controller | Date | Tue, 16 Aug 2022 08:27:50 +0000 |
| |
vm-pre-scalar-ch# is a per channel optional parameter that can be used to normalzie the voltage output results.
Signed-off-by: Eliav Farber <farbere@amazon.com> --- .../devicetree/bindings/hwmon/moortec,mr75203.yaml | 8 ++++++++ 1 file changed, 8 insertions(+)
diff --git a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml index 6111b5069b3c..e2a55001eefc 100644 --- a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml +++ b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml @@ -56,6 +56,12 @@ properties: A value of 0 means that the entire VM sensor is nou used. $ref: /schemas/types.yaml#definitions/uint8-array + vm-pre-scalar-ch#: + description: + vm-active-channels defines the pre-scalar per channel value + used to normalzie the voltage output results. + $ref: /schemas/types.yaml#definitions/uint32 + required: - compatible - reg @@ -68,6 +74,7 @@ additionalProperties: - intel,vm-map - reset-control-skip - vm-active-channels + - vm-pre-scalar-ch# examples: - | @@ -82,5 +89,6 @@ examples: clocks = <&osc0>; resets = <&rcu0 0x40 7>; vm-active-channels = [08 10 02]; + vm-pre-scalar-ch5 = <2>; #thermal-sensor-cells = <1>; }; -- 2.37.1
| |