| Date | Tue, 5 Jul 2022 19:21:01 +0200 | Subject | Re: [PATCH V2 09/13] OPP: Assert clk_count == 1 for single clk helpers | From | Krzysztof Kozlowski <> |
| |
On 05/07/2022 09:00, Viresh Kumar wrote: > Many helpers can be safely called only for devices that have a single > clk associated with them. Assert the same for those routines. >
Where is the safety problem with multiple-clocks case? And how users of PM OPP API are supposed to iterate/find OPPs they want if the API now throws WARN?
Best regards, Krzysztof
|