Messages in this thread | | | Date | Sun, 24 Jul 2022 20:27:54 +0200 | From | Daniel Lezcano <> | Subject | Re: [PATCH v1 17/33] thermal/drivers/rcar: Switch to new of API |
| |
Hi Niklas,
I tried to reproduce the issue but without success.
What sensor are you using ?
On 19/07/2022 11:10, Niklas Söderlund wrote: > Hi Daniel, > > Thanks for your work. > > On 2022-07-10 23:24:07 +0200, Daniel Lezcano wrote: >> The thermal OF code has a new API allowing to migrate the OF >> initialization to a simpler approach. >> >> Use this new API. > I tested this together with the series it depends on and while > temperature monitoring seems to work fine it breaks the emul_temp > interface (/sys/class/thermal/thermal_zone2/emul_temp). > > Before this change I can write a temperature to this file and have it > trigger actions, in my test-case changing the cooling state, which I > observe in /sys/class/thermal/cooling_device0/cur_state. > > Likewise before this change I could trip the critical trip-point that > would power off the board using the emul_temp interface, this too no > longer works, > > echo 120000 > /sys/class/thermal/thermal_zone2/emul_temp > > Is this an intention change of the new API?
| |