SubjectRe: [PATCH v5 3/5] drivers: thermal: tsens: allow configuring min and max trips
On Fri 08 Jul 08:29 CDT 2022, Robert Marko wrote:

> IPQ8074 and IPQ6018 dont support negative trip temperatures and support
> up to 204 degrees C as the max trip temperature.
>
> So, instead of always setting the -40 as min and 120 degrees C as max
> allow it to be configured as part of the features.
>
> Signed-off-by: Robert Marko <robimarko@gmail.com>

Reviewed-by: Bjorn Andersson <bjorn.andersson@linaro.org>

Regards,
Bjorn

\
 
 \ /