lkml.org 
[lkml]   [2022]   [Jun]   [9]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
SubjectRe: [PATCH] clk: ingenic-tcu: Properly enable registers before accessing timers
From
Date
Quoting Aidan MacDonald (2022-06-03 06:47:05)
> Access to registers is guarded by ingenic_tcu_{enable,disable}_regs()
> so the stop bit can be cleared before accessing a timer channel, but
> those functions did not clear the stop bit on SoCs with a global TCU
> clock gate.
>
> Testing on the X1000 has revealed that the stop bits must be cleared
> _and_ the global TCU clock must be ungated to access timer registers.
> Programming manuals for the X1000, JZ4740, and JZ4725B specify this
> behavior. If the stop bit isn't cleared, then writes to registers do
> not take effect, which can leave clocks with no defined parent when
> registered and leave clock tree state out of sync with the hardware,
> triggering bugs in downstream drivers relying on TCU clocks.
>
> Fixing this is easy: have ingenic_tcu_{enable,disable}_regs() always
> clear the stop bit, regardless of the presence of a global TCU gate.
>
> Signed-off-by: Aidan MacDonald <aidanmacdonald.0x0@gmail.com>
> ---

Any Fixes: tag?

\
 
 \ /
  Last update: 2022-06-10 00:44    [W:0.088 / U:1.676 seconds]