SubjectRe: [PATCH v2 3/3] mips: ingenic: Do not manually reference the CPU clock
From
Date
Quoting Aidan MacDonald (2022-04-28 09:44:54)
> It isn't necessary to manually walk the device tree and enable
> the CPU clock anymore. The CPU and other necessary clocks are
> now flagged as critical in the clock driver, which accomplishes
> the same thing in a more declarative fashion.
>
> Signed-off-by: Aidan MacDonald <aidanmacdonald.0x0@gmail.com>
> Reviewed-by: Paul Cercueil <paul@crapouillou.net>
> ---

Applied to clk-next

\
 
 \ /