Messages in this thread | | | Date | Wed, 11 May 2022 17:08:24 -0500 | Subject | Re: [PATCH 1/2] dt-bindings: iio: humidity: Add si7020 bindings | From | Eddie James <> |
| |
On 5/11/22 14:08, Eddie James wrote: > Document the si7020 bindings with a new "silabs,skip-reset" property.
I missed the entry in trivial-devices.txt. I can push a v2 or a separate patch for that.
Eddie
> > Signed-off-by: Eddie James <eajames@linux.ibm.com> > --- > .../bindings/iio/humidity/silabs,si7020.yaml | 42 +++++++++++++++++++ > 1 file changed, 42 insertions(+) > create mode 100644 Documentation/devicetree/bindings/iio/humidity/silabs,si7020.yaml > > diff --git a/Documentation/devicetree/bindings/iio/humidity/silabs,si7020.yaml b/Documentation/devicetree/bindings/iio/humidity/silabs,si7020.yaml > new file mode 100644 > index 000000000000..ab53bb8d9606 > --- /dev/null > +++ b/Documentation/devicetree/bindings/iio/humidity/silabs,si7020.yaml > @@ -0,0 +1,42 @@ > +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause) > +%YAML 1.2 > +--- > +$id: http://devicetree.org/schemas/iio/humidity/silabs,si7020.yaml# > +$schema: http://devicetree.org/meta-schemas/core.yaml# > + > +title: SI7020 humidity + temperature sensor > + > +maintainers: > + - David Barksdale <dbarksdale@uplogix.com> > + > +description: | > + The Silicon Labs Si7013/20/21 Relative Humidity and Temperature Sensors > + are i2c devices which have an identical programming interface for > + measuring relative humidity and temperature. > + > +properties: > + compatible: > + const: silabs,si7020 > + > + reg: > + maxItems: 1 > + > + siliabs,skip-reset: > + $ref: /schemas/types.yaml#/definitions/flag > + description: > + Disables resetting of the device during probe > + > +required: > + - compatible > + - reg > + > +additionalProperties: false > + > +examples: > + - | > + si7021-a20@40 { > + silabs,skip-reset; > + compatible = "silabs,si7020"; > + reg = <0x40>; > + }; > +...
| |