Messages in this thread | | | From | Rob Herring <> | Subject | Re: [Patch v8 3/4] dt-bindings: memory: tegra: Update validation for reg and reg-names | Date | Mon, 25 Apr 2022 08:31:19 -0500 |
| |
On Mon, 25 Apr 2022 13:20:35 +0530, Ashish Mhetre wrote: >
Running 'make dtbs_check' with the schema in this patch gives the following warnings. Consider if they are expected or the schema is incorrect. These may not be new warnings.
Note that it is not yet a requirement to have 0 warnings for dtbs_check. This will change in the future.
Full log is available here: https://patchwork.ozlabs.org/patch/
memory-controller@2c00000: reg: [[0, 46137344, 0, 720896]] is too short arch/arm64/boot/dts/nvidia/tegra186-p2771-0000.dtb arch/arm64/boot/dts/nvidia/tegra186-p2771-0000.dtb arch/arm64/boot/dts/nvidia/tegra186-p3509-0000+p3636-0001.dtb arch/arm64/boot/dts/nvidia/tegra186-p3509-0000+p3636-0001.dtb
memory-controller@2c00000: reg: [[46137344, 1048576], [45613056, 262144], [24117248, 1048576]] is too short arch/arm64/boot/dts/nvidia/tegra194-p2972-0000.dtb arch/arm64/boot/dts/nvidia/tegra194-p2972-0000.dtb arch/arm64/boot/dts/nvidia/tegra194-p3509-0000+p3668-0000.dtb arch/arm64/boot/dts/nvidia/tegra194-p3509-0000+p3668-0000.dtb arch/arm64/boot/dts/nvidia/tegra194-p3509-0000+p3668-0001.dtb arch/arm64/boot/dts/nvidia/tegra194-p3509-0000+p3668-0001.dtb arch/arm64/boot/dts/nvidia/tegra234-p3737-0000+p3701-0000.dtb arch/arm64/boot/dts/nvidia/tegra234-p3737-0000+p3701-0000.dtb arch/arm64/boot/dts/nvidia/tegra234-sim-vdk.dtb arch/arm64/boot/dts/nvidia/tegra234-sim-vdk.dtb
memory-controller@2c00000: 'reg-names' is a required property arch/arm64/boot/dts/nvidia/tegra186-p2771-0000.dtb arch/arm64/boot/dts/nvidia/tegra186-p3509-0000+p3636-0001.dtb arch/arm64/boot/dts/nvidia/tegra194-p2972-0000.dtb arch/arm64/boot/dts/nvidia/tegra194-p3509-0000+p3668-0000.dtb arch/arm64/boot/dts/nvidia/tegra194-p3509-0000+p3668-0001.dtb arch/arm64/boot/dts/nvidia/tegra234-p3737-0000+p3701-0000.dtb arch/arm64/boot/dts/nvidia/tegra234-sim-vdk.dtb
| |