Messages in this thread | | | Date | Sun, 27 Mar 2022 10:00:09 +0200 | Subject | Re: [PATCH v1 1/3] dt-bindings: clock: fix some conversion issues for rockchip,rk3399-cru.yaml | From | Krzysztof Kozlowski <> |
| |
On 26/03/2022 11:27, Johan Jonker wrote: > With the conversion of rockchip,rk3399-cru.txt some issues were added, > so fix them: > > Changed: > Align the table with external clocks. > Remove the original author in 2016 as maintainer.
This requires explanation.
> Change clocks maxItems.
This requires explanation. There is no maxItems in clocks.
> Add clock-names. > Use clock-controller node name in example.
Why?
> Remove assigned-xxx. > Remove ">" from description.
All this should be around two or three commits, so you need to split changes which are cleanups to changes affecting functionality (adding new properties, changing values).
> > Signed-off-by: Johan Jonker <jbx6244@gmail.com> > --- > .../bindings/clock/rockchip,rk3399-cru.yaml | 32 +++++++------------ > 1 file changed, 11 insertions(+), 21 deletions(-) >
Best regards, Krzysztof
| |