Before answering the questions, I’d like to address the motivation behind this patchset.
You know, InfiniBand/RoCE provides NVMe-oF a lossless network environment (that is zero packet loss), which is a great advantage to performance.
In contrast, 'TCP/IP + ethernet' is often used as a lossy network environment (packet dropping often occurs). And once packet dropping occurs, timeout-retransmission would be triggered. But once timeout-retransmission was triggered, bandwidth would drop to 0 all of a sudden. This is great damage to performance.
So although NVMe/TCP may have a bandwidth competitive to that of NVMe/RDMA, but the packet dropping of the former is a flaw to its performance.
However, with the combination of the following conditions, NVMe/TCP can become much more competitive to NVMe/RDMA in the data center.
- Ethernet NICs supporting QoS configuration (support mapping TOS/DSCP in IP header into priority, supporting adjusting buffer size of each priority, support PFC)
- Ethernet Switches supporting ECN marking, supporting adjusting buffer size of each priority.
- NVMe/TCP supports specifying the tos for its TCP traffic (already implemented)
- NVMe/TCP supports specifying dctcp as the congestion-control of its TCP sockets (the work of this feature)
So this feature is the last item from the software aspect to form up the above combination.
| |