Date
The new registration method allows to get power values from the DT OPP
definition. The new OPP entry property "opp-microwatt" contains total
power expressed in micro-Watts. Align the EM documentation with this
new possible registration method of 'advanced' EM.

Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
---
Documentation/power/energy-model.rst | 10 ++++++++++
1 file changed, 10 insertions(+)

diff --git a/Documentation/power/energy-model.rst b/Documentation/power/energy-model.rst
index 5ac62a7b4b7c..719253fd5215 100644
--- a/Documentation/power/energy-model.rst
+++ b/Documentation/power/energy-model.rst
@@ -113,6 +113,16 @@ to: return warning/error, stop working or panic.
See Section 3. for an example of driver implementing this
callback, or Section 2.4 for further documentation on this API

+Registration of 'advanced' EM using DT
+~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+
+The 'advanced' EM can also be registered using OPP framework and information
+in DT "operating-points-v2". Each OPP entry in DT can be extended with a
+property "opp-microwatt" containing micro-Watts power value. This OPP DT
+property allows a platform to register EM power values which are reflecting
+total power (static + dynamic). These power values might be coming directly
+from experiments and measurements.
+