Messages in this thread | | | Subject | Re: [PATCH v2 0/1] ipheth URB overflow fix | From | Yves-Alexis Perez <> | Date | Wed, 02 Feb 2022 18:01:07 +0100 |
| |
On Wed, 2022-02-02 at 12:35 +0200, Georgi Valkov wrote: > Without the patch I get EOVERFLOW and there is no further communication. > It would be nice if a failsafe mechanism is implemented to recover from > faults > like that or in the event that no communication is detected over a certain > period. > With the patch applied, everything works fine: > 1480 bytes from 10.98.8.1: icmp_seq=0 ttl=253 time=50.234 ms
Thanks for the steps. I can confirm that without the patch I get:
[ +4.516398] ipheth 1-3.3:4.2: ipheth_rcvbulk_callback: urb status: -75
and the interface doesn't work anymore.
With the patch applied, I get ping results and the network keeps going.
Regards, -- Yves-Alexis
| |