Messages in this thread | | | From | Martin Blumenstingl <> | Date | Sat, 26 Nov 2022 00:09:28 +0100 | Subject | Re: [PATCH 08/12] dt-bindings: timer: convert timer/amlogic,meson7-timer.txt to dt-schema |
| |
Hi Neil,
there's a typo in the subject line: it should be meson6-timer.txt (instead of meson7-timer.txt)
On Fri, Nov 18, 2022 at 3:33 PM Neil Armstrong <neil.armstrong@linaro.org> wrote: > > Convert the Amlogic Meson6 SoCs Timer Controller bindings to dt-schema. > > Signed-off-by: Neil Armstrong <neil.armstrong@linaro.org> If you re-send this with the subject updated and the per-timer interrupt description (that Krzysztof mentioned) added then please add my: Reviewed-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
| |