Hi Guenter,
On 20-11-2022 07:44 pm, Guenter Roeck wrote: > On Sat, Nov 19, 2022 at 07:25:16PM +0100, Naresh Solanki wrote: >> From: Patrick Rudolph <patrick.rudolph@9elements.com> >> >> Add get_status for pmbus_regulator_ops. >> >> Changes: >> - use lock throughout the function >> - Avoid line continuation upto 100 column >> - Optimize use of & and | operator >> - Check for VOUT, IOUT, TEMPERATURE bit in status word before checking >> respective status register for fault. >> - Report regulator current status. >> > Change log should be after '---' Sure > > Also, when looking into this, I realized that we already have > pmbus_regulator_get_error_flags() which has somewhat overlapping > functionality. Would it be possible to utilize that function to get > the error status instead of more or less hand-coding it ? Sure. But looking at get_status scope, I feel that we are already checking the following: 1. Check if regulator is off & yes then return off 2. If not off then it should be on & has power good then return on 3. If no power good then this itself is error condition so return error. Decoding status register for fault just double confirms that & may not be needed in get_status unless we are going to print or utilize the error bit information in some other way but that is out of scope of get_status call unless I missed something.
Does this approach makes sense ? > > Thanks, > Guenter
| |