Messages in this thread | | | Date | Wed, 2 Nov 2022 16:06:17 -0400 | Subject | Re: [PATCH v2 01/12] dt-bindings: iio: qcom: adc7-pm8350: Allow specifying SID for channels | From | Krzysztof Kozlowski <> |
| |
On 29/10/2022 01:14, Manivannan Sadhasivam wrote: > As per the new ADC7 architecture used by the Qualcomm PMICs, each PMIC > has the static Slave ID (SID) assigned by default. The primary PMIC > PMK8350 is responsible for collecting the temperature/voltage data from > the slave PMICs and exposing them via it's registers. > > For getting the measurements from the slave PMICs, PMK8350 uses the > channel ID encoded with the SID of the relevant PMIC. So far, the > dt-binding for the slave PMIC PM8350 assumed that there will be only > one PM8350 in a system. So it harcoded SID 1 with channel IDs. > > But this got changed in platforms such as Lenovo X13s where there are a > couple of PM8350 PMICs available. So to address multiple PM8350s, change > the binding to accept the SID specified by the user and use it for > encoding the channel ID. > > It should be noted that, even though the SID is static it is not > globally unique. Only the primary PMIC has the unique SID id 0. > > Signed-off-by: Manivannan Sadhasivam <manivannan.sadhasivam@linaro.org>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Best regards, Krzysztof
| |