SubjectRe: [PATCH v4 1/3] dt-bindings: hwmon: fan: Add fan binding to schema
From


On 24-10-2022 09:48 pm, Rob Herring wrote:
> So if we unload and reload the driver module, it should go back to the
> default?
This is RPM to be set during probe if desired.
>
> I think it is really, 'target RPM if not already configured' which could
> be keep the setting from a register (e.g. what the bootloader set) or
> perhaps you already have temperature information to use...
Yes. missed it. It should be target-rpm will correct this. in next version.
>
>> + $ref: /schemas/types.yaml#/definitions/uint32
>> + pwm-frequency:
>> + description:
>> + PWM frequency for fan in Hertz(Hz).
>> + $ref: /schemas/types.yaml#/definitions/uint32
>> +
>> + pwm-polarity-inverse:
>> + description:
>> + Inverse PWM polarity for fan.
>> + type: boolean
> As I said before, the PWM binding handles these 2 settings. Use it. Yes,
> it's a bit of an overkill when the child is the consumer of the parent.
> Until some 'clever' h/w engineer decides to use one of the PWMs for
> something else like a backlight.
I would like you to consider this as something recommended by fan
datasheet for the given fan instance.
This info can be used by fan controller driver to configure PWM
source/provider accordingly.

If you still feel that may not make sense then I'll remove this property.


Thanks,
Naresh

\
 
 \ /