Messages in this thread | | | Date | Mon, 17 Oct 2022 12:01:00 +0100 | Subject | Re: [PATCH v6 4/8] scsi: hisi_sas: Modify v3 HW SATA disk error state completion processing | From | John Garry <> |
| |
On 17/10/2022 11:45, Niklas Cassel wrote: > On Mon, Oct 17, 2022 at 05:20:31PM +0800, John Garry wrote: >> From: Xingui Yang<yangxingui@huawei.com> >> >> When an NCQ error occurs, the controller will abnormally complete the I/Os >> that are newly delivered to disk, and bit8 in CQ dw3 will be set which >> indicates that the SATA disk is in error state. The current processing flow >> is to set ts->stat to SAS_OPEN_REJECT and then sas_ata_task_done() will >> set FIS stat to ATA_ERR. After analyzing the IO by ata_eh_analyze_tf(), >> err_mask will set to AC_ERR_HSM. If media error occurs for four times >> within 10 minutes and the chip rejects new I/Os for four times, NCQ will >> be disabled due to excessive errors, which is undesirable. > With patch 8/8 in this series, will it still set err_mask to AC_ERR_HSM? > If not, is this patch still needed with patch 8/8? >
I spoke to colleague Xingui Yang and he does not think that it is still required. But I was leaving it in as it still looked like a sensible change. I suppose I can drop it.