Messages in this thread | | | Date | Mon, 17 Oct 2022 09:25:28 +0200 | Subject | Re: [PATCH v3] thermal: imx8mm_thermal: validate temperature range | From | Daniel Lezcano <> |
| |
On 14/10/2022 09:35, Marcus Folkesson wrote: > Check against the upper temperature limit (125 degrees C) before > consider the temperature valid. > > Fixes: 5eed800a6811 ("thermal: imx8mm: Add support for i.MX8MM thermal monitoring unit") > Signed-off-by: Marcus Folkesson <marcus.folkesson@gmail.com> > ---
Applied, thanks
-- <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs