On Wed, Jan 26, 2022 at 1:06 PM Greg KH <gregkh@linuxfoundation.org> wrote:
>
> On Mon, Jan 10, 2022 at 12:49:26PM +0100, Sergio Paracuellos wrote:
> > Hi all,
> >
> > This patch series add minimal change to provide mt7621 resets properly
> > defining them in the 'mediatek,mt7621-sysc' node which is the system
> > controller of the SoC and is already providing clocks to the rest of
> > the world.
> >
> > There is shared architecture code for all ralink platforms in 'reset.c'
> > file located in 'arch/mips/ralink' but the correct thing to do to align
> > hardware with software seems to define and add related reset code to the
> > already mainlined clock driver.
> >
> > After this changes, we can get rid of the useless reset controller node
> > in the device tree and use system controller node instead where the property
> > '#reset-cells' has been added. Binding documentation for this nodeq has
> > been updated with the new property accordly.
> >
> > This series also provide a bindings include header where all related
> > reset bits for the MT7621 SoC are defined.
> >
> > Also, please take a look to this review [0] to understand better motivation
> > for this series.
> >
> > Regarding the way of merging this:
> > - I'd like patches 1 and 4 which are related going through staging tree.
>
> Patches 1 and 4 now in the staging tree, thanks.

Stephen wanted all to go through the CLK tree since PATCH 3 and 1 were
also a dependency... Can we get all of them through the same tree,
then? I am ok with both CLK or staging trees.

Thanks,
Sergio Paracuellos
>
> greg k-h
>

\
 
 \ /
  Last update: 2022-01-26 13:09    [W:0.191 / U:0.304 seconds]