Messages in this thread | | | Date | Tue, 25 Jan 2022 00:40:01 +0800 | Subject | Re: [PATCH v5 8/8] KVM: VMX: Resize PID-ponter table on demand for IPI virtualization | From | Zeng Guang <> |
| |
On 1/20/2022 9:01 AM, Sean Christopherson wrote: > On Wed, Jan 19, 2022, Zeng Guang wrote: >> It's self-adaptive , standalone function module in kvm, no any extra >> limitation introduced > I disagree. Its failure mode on OOM is to degrade guest performance, _that_ is > a limitation. OOM is absolutely something that should be immediately communicated > to userspace in a way that userspace can take action. If memory allocation fails, PID-pointer table stop updating and keep using the old one. All IPIs from other vcpus will go through APIC-Write VM-exits and won't get performance improvement from IPI virtualization to this new created vcpu. Right, it's a limitation though it doesn't impact the effectiveness of IPI virtualization among existing vcpus. >> and scalable even future extension on KVM_MAX_VCPU_IDS or new apic id >> implementation released. >> >> How do you think ? :) > Heh, I think I've made it quite clear that I think it's unnecesary complexity in > KVM. It's not a hill I'll die on, e.g. if Paolo and others feel it's the right > approach then so be it, but I really, really dislike the idea of dynamically > changing the table, KVM has a long and sordid history of botching those types > of flows/features.
To follow your proposal, we think about the feasible implementation as follows: 1. Define new parameter apic_id_limit in struct kvm_arch and initialized as KVM_MAX_VCPU_IDS by default.
2. New vm ioclt KVM_SET_APICID_LIMIT to allow user space set the possible max apic id required in the vm session before vcpu creation. Currently QEMU calculates the limit to CPU APIC ID up to max cpus assigned for hotpluggable cpu. It simply uses package/die/core/smt model to get bit width of id field on each level (not totally comply with CPUID 1f/0b) and make apic id for specific vcpu index. We can notify kvm this apic id limit to ensure memory enough for PID-table.
3. Need check whether id is less than min(apic_id_limit, KVM_MAX_VCPU_IDS) in vcpu creation. Otherwise return error.
4. Allocate memory covering vcpus with the id up to apic_id_limit for PID table during the first vcpu creation. Proper lock still needed to protect PID table setup from race condition. If OOM happens, current vcpu creation fails either and return error back to user space.