On 9/6/21 10:40 AM, Hannes Reinecke wrote: > On 9/6/21 10:01 AM, Christoph Hellwig wrote: >> On Thu, Sep 02, 2021 at 11:20:02AM +0200, Daniel Wagner wrote: >>> When we remove the siblings entry, we update ns->head->list, hence we >>> can't separate the removal and test for being empty. They have to be >>> in the same critical section to avoid a race. >>> >>> To avoid breaking the refcounting imbalance again, add a list empty >>> check to nvme_find_ns_head. >> >> Hannes, can you look over this and run your tests on it? >> > I'm at it. > Finally. qemu being it's usual bitchy self.
But managed to test the patch, and all looks good.
For reference, the testcase is:
- Create qemu instance with two NVMe namespaces: -device pcie-root-port,id=rp80,bus=pcie.0,chassis=2,addr=8.0,\ multifunction=on,pref64-reserve=32M \ -device pcie-root-port,id=rp90,bus=pcie.0,chassis=3,addr=9.0,\ multifunction=on,pref64-reserve=32M \ -device nvme-subsys,id=nvme-subsys1,nqn=slesnvmesubsys-1 \ -device nvme-subsys,id=nvme-subsys2,nqn=slesnvmesubsys-2 \ -device nvme,bus=rp80,id=nvme-rp80,serial=SLESNVME2,\ subsys=nvme-subsys1 \ -device nvme-ns,id=nvme-ns-2,bus=nvme-rp80,drive=nvme-2 \ -device nvme,bus=rp90,id=nvme-rp90,serial=SLESNVME3,\ subsys=nvme-subsys2 \ -device nvme-ns,id=nvme-ns-3,bus=nvme-rp90,drive=nvme-3
- Install the system, and create an MD RAID 1 on those namespaces. - Enter qemu monitor, and detach one controller: device_del nvme-rp90 - Check in the OS that the device has been removed, and MD has registered the device failure:
# dmesg [ 1801.076236] pcieport 0000:00:09.0: pciehp: Slot(0-2): Attention button pressed [ 1801.076251] pcieport 0000:00:09.0: pciehp: Slot(0-2): Powering off due to button press [ 1806.250017] block nvme2n1: no available path - failing I/O [ 1806.250030] md: super_written gets error=-5 [ 1806.250036] md/raid1:md1: Disk failure on nvme2n1, disabling device. md/raid1:md1: Operation continuing on 1 devices.
- Enter qemu monitor, and re-attach the controller: device_add bus=rp90,id=nvme-rp90,serial=SLESNVME3,subsys=nvme-subsys2
- Check in the OS that the device has been reattached: # dmesg [ 1845.634613] pcieport 0000:00:09.0: pciehp: Slot(0-2): Attention button pressed [ 1845.634626] pcieport 0000:00:09.0: pciehp: Slot(0-2) Powering on due to button press [ 1845.634821] pcieport 0000:00:09.0: pciehp: Slot(0-2): Card present [ 1845.634826] pcieport 0000:00:09.0: pciehp: Slot(0-2): Link Up [ 1845.770969] pci 0000:03:00.0: [1b36:0010] type 00 class 0x010802 [ 1845.771307] pci 0000:03:00.0: reg 0x10: [mem 0x00000000-0x00003fff 64bit] [ 1845.773503] pci 0000:03:00.0: BAR 0: assigned [mem 0xc1200000-0xc1203fff 64bit] [ 1845.773646] pcieport 0000:00:09.0: PCI bridge to [bus 03] [ 1845.773671] pcieport 0000:00:09.0: bridge window [io 0x7000-0x7fff] [ 1845.776926] pcieport 0000:00:09.0: bridge window [mem 0xc1200000-0xc13fffff] [ 1845.778816] pcieport 0000:00:09.0: bridge window [mem 0x804000000-0x805ffffff 64bit pref] [ 1845.783970] nvme nvme2: pci function 0000:03:00.0 [ 1845.784227] nvme 0000:03:00.0: enabling device (0000 -> 0002) [ 1845.798918] nvme nvme2: 1/0/0 default/read/poll queues
- Reattach the namespace to the MD RAID: # mdadm --manage /dev/md1 --re-add /dev/nvme2n1
- Check that everything worked: # # cat /proc/mdstat Personalities : [raid1] md1 : active raid1 nvme2n1[1] nvme1n1[0] 4189184 blocks super 1.2 [2/2] [UU] bitmap: 0/1 pages [0KB], 65536KB chunk
unused devices: <none>
So you can add:
Reviewed-by: Hannes Reinecke <hare@suse.de> Tested-by: Hannes Reinecke <hare@suse.de>
Cheers,
Hannes -- Dr. Hannes Reinecke Kernel Storage Architect hare@suse.de +49 911 74053 688 SUSE Software Solutions Germany GmbH, Maxfeldstr. 5, 90409 Nürnberg HRB 36809 (AG Nürnberg), GF: Felix Imendörffer
| |