Messages in this thread | | | Subject | Re: Faulty commit "watchdog: iTCO_wdt: Account for rebooting on second timeout" | From | Jan Kiszka <> | Date | Wed, 4 Aug 2021 08:58:16 +0200 |
| |
On 04.08.21 02:04, Michael Marley wrote: > On 8/3/21 10:59 AM, Jan Kiszka wrote: > >> https://lkml.org/lkml/2021/7/26/349 >> > > It fixes the problem for me (the person who opened the Bugzilla report) > too, thanks! > > Tested-by: Michael Marley <michael@michaelmarley.com> >
Thanks for the confirmation!
Yeah, sorry, that original mistake is truly mine. In fact, I wrote this code twice [1] but only messed it up here. Unfortunate that it spread so quickly. I'll try discuss this with stable people eventually, if it was a one off or if there are more such cases.
Jan
[1] https://github.com/siemens/efibootguard/commit/aa89fe3cbd883198c23eaec43c4448fe9e8ae148
-- Siemens AG, T RDA IOT Corporate Competence Center Embedded Linux
| |