Messages in this thread | | | From | David Laight <> | Subject | RE: [PATCH] scsi: BusLogic: use %X for u32 sized integer rather than %lX | Date | Mon, 2 Aug 2021 08:11:42 +0000 |
| |
From: Colin King > Sent: 30 July 2021 10:51 > > From: Colin Ian King <colin.king@canonical.com> > > An earlier fix changed the print format specifier for adapter->bios_addr > to use %lX however the integer is a u32 so the fix was wrong. Fix this > by using the correct %X format specifier.
Is that right? I bet one 32bit arch defines u32 as long.
David