Messages in this thread Patch in this message | | | From | Sergio Paracuellos <> | Subject | [PATCH] clk: ralink: avoid to set 'CLK_IS_CRITICAL' flag for gates | Date | Tue, 27 Jul 2021 07:55:37 +0200 |
| |
'clk_init_data' for gates is setting up 'CLK_IS_CRITICAL' flag for all of them. This was being doing because some drivers of this SoC might not be ready to use the clock and we don't wanted the kernel to disable them since default behaviour without clock driver was to set all gate bits to enabled state. After a bit more testing and checking driver code it is safe to remove this flag and just let the kernel to disable those gates that are not in use. No regressions seems to appear.
Fixes: 48df7a26f470 ("clk: ralink: add clock driver for mt7621 SoC") Signed-off-by: Sergio Paracuellos <sergio.paracuellos@gmail.com> --- drivers/clk/ralink/clk-mt7621.c | 9 +-------- 1 file changed, 1 insertion(+), 8 deletions(-)
diff --git a/drivers/clk/ralink/clk-mt7621.c b/drivers/clk/ralink/clk-mt7621.c index 857da1e274be..a2c045390f00 100644 --- a/drivers/clk/ralink/clk-mt7621.c +++ b/drivers/clk/ralink/clk-mt7621.c @@ -131,14 +131,7 @@ static int mt7621_gate_ops_init(struct device *dev, struct mt7621_gate *sclk) { struct clk_init_data init = { - /* - * Until now no clock driver existed so - * these SoC drivers are not prepared - * yet for the clock. We don't want kernel to - * disable anything so we add CLK_IS_CRITICAL - * flag here. - */ - .flags = CLK_SET_RATE_PARENT | CLK_IS_CRITICAL, + .flags = CLK_SET_RATE_PARENT, .num_parents = 1, .parent_names = &sclk->parent_name, .ops = &mt7621_gate_ops, -- 2.25.1
| |