Messages in this thread | | | Date | Fri, 23 Jul 2021 15:28:40 +0300 | From | "" <> | Subject | Re: [PATCH v1 1/1] serial: max310x: Use clock-names property matching to recognize XTAL |
| |
On Thu, Jul 22, 2021 at 09:05:13PM +0000, Dennis Giaya wrote: > Andy, > > I've tested this out on my hardware that uses an external oscillator > 'osc' (as opposed to external crystal 'xtal'). > > With the relevant asl > Package () {"compatible", "maxim,max14830"}, > Package () > {"clock-frequency", 19200000}, > Package () {"clock-names", "osc"}, > > Previously, the driver logic would default to 'xtal' and then compare > against the narrower frequency range and throw an error because 19.2MHz > was not allowed. With your patch, it proceeds as 'osc' and appears to > work as intended.
Thanks for testing! I assume I may convert above to the Tested-by: or equivalent tag.
JFYI, in OSS mailing lists we do not top post.
-- With Best Regards, Andy Shevchenko
| |