Messages in this thread | | | Date | Sun, 6 Jun 2021 23:30:54 +0200 | From | Uwe Kleine-König <> | Subject | Re: [PATCH v2 2/7] pwm: core: Always require PWM flags to be provided |
| |
Hello Andy,
On Mon, May 31, 2021 at 10:49:42PM +0300, Andy Shevchenko wrote: > It makes little sense to make PWM flags optional since in case > of multi-channel consumer the flags can be optional only for > the last listed channel.
I think the same holds true for dt references.
> Thus always require PWM flags to be provided.
I'm not sure I want to follow that conclusion. Most consumers only need a single PWM and then not providing flags is fine, isn't it? Or does this change fix an error?
Best regards Uwe