From
Subject[RFC PATCH v2 10/11] clocksource: clint: Add support for ACLINT MTIMER device
Date
The RISC-V ACLINT specification is a modular specification and the
ACLINT MTIMER device is backward compatible with the M-mode timer
functionality of the CLINT device. This patch extends the CLINT
timer driver to support both CLINT device and ACLINT MTIMER device.

Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Bin Meng <bmeng.cn@gmail.com>
---
drivers/clocksource/timer-clint.c | 35 ++++++++++++++++++++++---------
1 file changed, 25 insertions(+), 10 deletions(-)

diff --git a/drivers/clocksource/timer-clint.c b/drivers/clocksource/timer-clint.c
index 3b68ed53fe4a..bf89744cd12a 100644
--- a/drivers/clocksource/timer-clint.c
+++ b/drivers/clocksource/timer-clint.c
@@ -2,8 +2,16 @@
/*
* Copyright (C) 2020 Western Digital Corporation or its affiliates.
*
- * Most of the M-mode (i.e. NoMMU) RISC-V systems usually have a
- * CLINT MMIO timer device.
+ * Most of the M-mode (i.e. NoMMU) RISC-V systems usually have a CLINT
+ * MMIO device which is a composite device capable of injecting M-mode
+ * software interrupts and M-mode timer interrupts.
+ *
+ * The RISC-V ACLINT specification is modular in nature and defines
+ * separate devices for M-mode software interrupt (MSWI), M-mode timer
+ * (MTIMER) and S-mode software interrupt (SSWI).
+ *
+ * This is a common timer driver for the CLINT device and the ACLINT
+ * MTIMER device.
*/

#define pr_fmt(fmt) "clint: " fmt
@@ -21,25 +29,26 @@
#include <linux/smp.h>
#include <linux/timex.h>

-#ifndef CONFIG_RISCV_M_MODE
+#ifdef CONFIG_RISCV_M_MODE
#include <asm/clint.h>
+
+u64 __iomem *clint_time_val;
+EXPORT_SYMBOL(clint_time_val);
#endif

#define CLINT_IPI_OFF 0
#define CLINT_TIMER_CMP_OFF 0x4000
#define CLINT_TIMER_VAL_OFF 0xbff8

+#define ACLINT_MTIMER_CMP_OFF 0x0000
+#define ACLINT_MTIMER_VAL_OFF 0x7ff8
+
/* CLINT manages IPI and Timer for RISC-V M-mode */
static u64 __iomem *clint_timer_cmp;
static u64 __iomem *clint_timer_val;
static unsigned long clint_timer_freq;
static unsigned int clint_timer_irq;

-#ifdef CONFIG_RISCV_M_MODE
-u64 __iomem *clint_time_val;
-EXPORT_SYMBOL(clint_time_val);
-#endif
-
#ifdef CONFIG_64BIT
#define clint_get_cycles() readq_relaxed(clint_timer_val)
#else
@@ -170,8 +179,13 @@ static int __init clint_timer_init_dt(struct device_node *np)
return -ENODEV;
}

- clint_timer_cmp = base + CLINT_TIMER_CMP_OFF;
- clint_timer_val = base + CLINT_TIMER_VAL_OFF;
+ if (of_device_is_compatible(np, "riscv,aclint-mtimer")) {
+ clint_timer_cmp = base + ACLINT_MTIMER_CMP_OFF;
+ clint_timer_val = base + ACLINT_MTIMER_VAL_OFF;
+ } else {
+ clint_timer_cmp = base + CLINT_TIMER_CMP_OFF;
+ clint_timer_val = base + CLINT_TIMER_VAL_OFF;
+ }
clint_timer_freq = riscv_timebase;

#ifdef CONFIG_RISCV_M_MODE
@@ -219,3 +233,4 @@ static int __init clint_timer_init_dt(struct device_node *np)

TIMER_OF_DECLARE(clint_timer, "riscv,clint0", clint_timer_init_dt);
TIMER_OF_DECLARE(clint_timer1, "sifive,clint0", clint_timer_init_dt);
+TIMER_OF_DECLARE(clint_timer2, "riscv,aclint-mtimer", clint_timer_init_dt);
--
2.25.1
\
 
 \ /