Messages in this thread Patch in this message | | | From | Erwan Le Ray <> | Subject | [PATCH v2 3/4] dt-bindings: serial: 8250: update TX FIFO trigger level | Date | Tue, 13 Apr 2021 19:40:14 +0200 |
| |
Remove data type from tx-threshold trigger level as defined now as a serial generic property.
Signed-off-by: Erwan Le Ray <erwan.leray@foss.st.com>
diff --git a/Documentation/devicetree/bindings/serial/8250.yaml b/Documentation/devicetree/bindings/serial/8250.yaml index c0e292cdaa6b..ff0fa9b2a390 100644 --- a/Documentation/devicetree/bindings/serial/8250.yaml +++ b/Documentation/devicetree/bindings/serial/8250.yaml @@ -166,7 +166,6 @@ properties: property. tx-threshold: - $ref: /schemas/types.yaml#/definitions/uint32 description: | Specify the TX FIFO low water indication for parts with programmable TX FIFO thresholds. -- 2.17.1
| |