Messages in this thread | | | Date | Wed, 31 Mar 2021 18:35:45 +0200 | From | Andrew Lunn <> | Subject | Re: [EXTERNAL] Re: [PATCH] net: phy: dp83867: perform soft reset and retain established link |
| |
> > as per datasheet: https://www.ti.com/lit/ds/symlink/dp83867cr.pdf > > > 8.6.26 Control Register (CTRL) > > do SW_RESTART to perform a reset not including the registers and is > > acceptable to do this if a link is already present. > > > > I don't see any code here to determine if the like is present. What if > the cable is not plugged in? > > This API is primarily used for reset. Link Status is checked thru different > register. This shall not impact the cable plug in/out. With this change, it > will align with DP83822 driver API.
So why is there the comment:
> > and is > > acceptable to do this if a link is already present.
That kind of says, it is not acceptable to do this if the link is not present. Which is why i'm asking.