Subject[PATCH net] netsec: restore phy power state after controller reset
Date
Since commit 8e850f25b581 ("net: socionext: Stop PHY before resetting
netsec") netsec_netdev_init() power downs phy before resetting the
controller. However, the state is not restored once the reset is
complete. As a result it is not possible to bring up network on a
platform with Broadcom BCM5482 phy.

Fix the issue by restoring phy power state after controller reset is
complete.

Fixes: 8e850f25b581 ("net: socionext: Stop PHY before resetting netsec")
Cc: stable@vger.kernel.org
Signed-off-by: Mian Yousaf Kaukab <ykaukab@suse.de>
---
drivers/net/ethernet/socionext/netsec.c | 9 ++++++---
1 file changed, 6 insertions(+), 3 deletions(-)

diff --git a/drivers/net/ethernet/socionext/netsec.c b/drivers/net/ethernet/socionext/netsec.c
index 3c53051bdacf..200785e703c8 100644
--- a/drivers/net/ethernet/socionext/netsec.c
+++ b/drivers/net/ethernet/socionext/netsec.c
@@ -1715,14 +1715,17 @@ static int netsec_netdev_init(struct net_device *ndev)
goto err1;

/* set phy power down */
- data = netsec_phy_read(priv->mii_bus, priv->phy_addr, MII_BMCR) |
- BMCR_PDOWN;
- netsec_phy_write(priv->mii_bus, priv->phy_addr, MII_BMCR, data);
+ data = netsec_phy_read(priv->mii_bus, priv->phy_addr, MII_BMCR);
+ netsec_phy_write(priv->mii_bus, priv->phy_addr, MII_BMCR,
+ data | BMCR_PDOWN);

ret = netsec_reset_hardware(priv, true);
if (ret)
goto err2;

+ /* Restore phy power state */
+ netsec_phy_write(priv->mii_bus, priv->phy_addr, MII_BMCR, data);
+
spin_lock_init(&priv->desc_ring[NETSEC_RING_TX].lock);
spin_lock_init(&priv->desc_ring[NETSEC_RING_RX].lock);

--