lkml.org 
[lkml]   [2021]   [Feb]   [17]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
SubjectRe: [PATCH v2] IMA: support for duplicate data measurement
From
Date
Thanks for the feedback Mimi.
Appreciate it.

On 2021-02-17 7:03 a.m., Mimi Zohar wrote:
> Hi Tushar,
>
> The Subject line could be improved. Perhaps something like - "IMA:
> support for duplicate measurement records"
>
Will do.

> On Tue, 2021-02-16 at 18:46 -0800, Tushar Sugandhi wrote:
>> IMA does not measure duplicate data since TPM extend is a very expensive
>> operation. However, in some cases, the measurement of duplicate data
>> is necessary to accurately determine the current state of the system.
>> Eg, SELinux state changing from 'audit', to 'enforcing', and back to
>> 'audit' again. In this example, currently, IMA will not measure the
>> last state change to 'audit'. This limits the ability of attestation
>> services to accurately determine the current state of the measurements
>> on the system.
>
> This patch description is written from your specific usecase
> perspective, but it impacts file and buffer data measurements as well,
> not only critical data measurements. In all of these situations, with
> this patch a new measurement record is added/appended to the
> measurement list. Please re-write the patch description making it more
> generic.
>
> For example, I would start with something like, "IMA does not include
> duplicate file, buffer or critical data measurement records ..."
>
Agreed.
I will generalize the description further and send the v3 for review.

Thanks,
Tushar

> thanks,
>
> Mimi
>
>>
>> Update ima_add_template_entry() to support measurement of duplicate
>> data, driven by a Kconfig option - IMA_DISABLE_HTABLE.
>>
>> Signed-off-by: Tushar Sugandhi <tusharsu@linux.microsoft.com>

\
 
 \ /
  Last update: 2021-02-17 19:55    [W:0.074 / U:0.428 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site