lkml.org 
[lkml]   [2021]   [Feb]   [1]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH] i2c: mv64xxx: Add runtime PM support
On Sun, Jan 03, 2021 at 04:51:46AM -0600, Samuel Holland wrote:
> To save power, gate the clock when the bus is inactive, during system
> sleep, and during shutdown. On some platforms, specifically Allwinner
> A13/A20, gating the clock implicitly resets the module as well. Since
> the module already needs to be reset after some suspend/resume cycles,
> it is simple enough to reset it during every runtime suspend/resume.
>
> Because the bus may be used by wakeup source IRQ threads, it needs to
> be functional as soon as IRQs are enabled. Thus, its system PM hooks
> need to run in the noirq phase.
>
> Signed-off-by: Samuel Holland <samuel@sholland.org>

Applied to for-next with Gregory's ack, thanks!

[unhandled content-type:application/pgp-signature]
\
 
 \ /