Messages in this thread
/
SubjectRe: [PATCH 1/3] ALSA: hda/tegra: Skip reset on BPMP devices
From
Date


On 12/7/2021 9:05 PM, Dmitry Osipenko wrote:
> External email: Use caution opening links or attachments
>
>
> 07.12.2021 17:49, Sameer Pujar пишет:
> ...
>>>> How the reload case would be different? Can you please specify more
>>>> details if you are referring to a particular scenario?
>>> You have a shared power domain. Since power domain can be turned off
>>> only when nobody keeps domain turned on, you now making reset of HDA
>>> controller dependent on the state of display driver.
>> I don't think that the state of display driver would affect. The HDA
>> driver itself can issue unpowergate calls which in turn ensures h/w
>> reset. If display driver is already runtime active, HDA driver runtime
>> resume after this would be still fine since h/w reset is already applied
>> during display runtime resume. Note that both HDA and display resets are
>> connected to this power-domain and BPMP applies these resets during
>> unpowergate.
> HDA won't be reset while display is active on T186+.

No. HDA reset is applied whenever power-domain is ungated. It can happen
when either HDA or display device becomes active. So I don't think that
it is inconsistent.

\
 
 \ /