SubjectRe: [PATCH 1/3] ALSA: hda/tegra: Skip reset on BPMP devices
From
Date
07.12.2021 13:22, Dmitry Osipenko пишет:
> 07.12.2021 09:32, Sameer Pujar пишет:
>> HDA regression is recently reported on Tegra194 based platforms.
>> This happens because "hda2codec_2x" reset does not really exist
>> in Tegra194 and it causes probe failure. All the HDA based audio
>> tests fail at the moment. This underlying issue is exposed by
>> commit c045ceb5a145 ("reset: tegra-bpmp: Handle errors in BPMP
>> response") which now checks return code of BPMP command response.
>>
>> The failure can be fixed by avoiding above reset in the driver,
>> but the explicit reset is not necessary for Tegra devices which
>> depend on BPMP. On such devices, BPMP ensures reset application
>> during unpowergate calls. Hence skip reset on these devices
>> which is applicable for Tegra186 and later.
>
> The power domain is shared with the display, AFAICS. The point of reset
> is to bring h/w into predictable state. It doesn't make sense to me to
> skip the reset.
>
> If T194+ doesn't have hda2codec_2x reset, then don't request that reset
> for T194+.
>

I don't see the problem in the driver. It's only the device-tree that is
wrong. This hda_tegra.c patch should be unneeded, please fix only the
device-tree.

\
 
 \ /