lkml.org 
[lkml]   [2021]   [Nov]   [10]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
SubjectRe: [PATCH v2 27/45] mfd: ntxec: Use devm_register_power_handler()
From
Date
10.11.2021 13:43, Jonathan Neuschäfer пишет:
> On Mon, Nov 08, 2021 at 02:36:42PM +0300, Dmitry Osipenko wrote:
>> 08.11.2021 14:22, Jonathan Neuschäfer пишет:
>>> On Sun, Nov 07, 2021 at 08:42:33PM +0300, Dmitry Osipenko wrote:
>>> [...]
>>>> EC drivers tend to use higher priority in general. Jonathan, could you
>>>> please confirm that NTXEC driver is a more preferable restart method
>>>> than the watchdog?
>>>
>>> Yes. The original firmware uses the NTXEC to restart, and it works well,
>>> so I do think it's preferable.
>>
>> Thank you, then I'll update the NTXEC patch like this:
>>
>> https://github.com/grate-driver/linux/commit/22da3d91f1734d9a0ed036220ad4ea28465af988
>
> I tested again, but sys_off_handler_reboot called a bogus pointer
> (probably reboot_prepare_cb). I think it was left uninitialized in
> ntxec_probe, which uses devm_kmalloc. I guess we could switch it to
> devm_kzalloc:
>
> diff --git a/drivers/mfd/ntxec.c b/drivers/mfd/ntxec.c
> index 1f55dfce14308..30364beb4b1d0 100644
> --- a/drivers/mfd/ntxec.c
> +++ b/drivers/mfd/ntxec.c
> @@ -144,7 +144,7 @@ static int ntxec_probe(struct i2c_client *client)
> const struct mfd_cell *subdevs;
> size_t n_subdevs;
>
> - ec = devm_kmalloc(&client->dev, sizeof(*ec), GFP_KERNEL);
> + ec = devm_kzalloc(&client->dev, sizeof(*ec), GFP_KERNEL);
> if (!ec)
> return -ENOMEM;
>
>
>
> With that done, it works flawlessly.

Good catch, thank you! I'll correct this patch and add yours t-b.

\
 
 \ /
  Last update: 2021-11-10 14:39    [W:0.325 / U:0.104 seconds]