SubjectRe: [PATCH v3 03/13] net: phy: at803x: improve the WOL feature
From
Date

On 10/19/2021 8:29 PM, Andrew Lunn wrote:
>> Hi Andrew,
>>
>> when this register AT803X_INTR_STATUS bits are cleared after read, we can't
>> clear only WOL interrupt here.
> O.K. But you do have the value of the interrupt status register. So
> you could call phy_trigger_machine(phydev) if there are any other
> interrupt pending. They won't get lost that way.
>
> Andrew
This make sense, thanks for this comment, will add it in the next patch set.

\
 
 \ /