SubjectRe: [PATCH 1/4] net: sfp: add workaround for Realtek RTL8672 and RTL9601C chips
On Wed, Jan 06, 2021 at 03:21:38PM +0000, Russell King - ARM Linux admin wrote:
> On Wed, Jan 06, 2021 at 03:55:32PM +0100, Pali Rohár wrote:
> > On my tested CarlitoxxPro module is:
> >
> > Option values : 0x00 0x1c
> > Option : RX_LOS implemented, inverted
> > Option : TX_FAULT implemented
> > Option : TX_DISABLE implemented
> >
> > When cable is disconnected then in EEPROM at position 0x16e is value
> > 0x82. If I call 'ip link set eth1 up' then value changes to 0x02, module
> > itself has a link and I can connect to its internal telnet/webserver to
> > configure it.
>
> Bit 7 reflects the TX_DISABLE pin state. Bit 1 reflects the RX_LOS pin
> state. It isn't specified whether the inverted/non-inverted state is
> reflected in bit 1 or not - the definition just says that bit 1 is
> "Digital state of the RX_LOS Output Pin."
>
> > I also tested UBNT module and result is:
> >
> > Option values : 0x00 0x06
> > Option : RX_LOS implemented
> > Option : RX_LOS implemented, inverted
> >
> > Which means that those bits are not implemented.
> >
> > Anyway I check position 0x16e and value on its value is randomly either
> > 0x79 or 0xff independently of the state of the GPON module.
> >
> > So it is really not implemented on UBNT.
>
> There are enhanced options at offset 93 which tell you which of the
> offset 110 signals are implemented.

That's the ID EEPROM (A0) offset 93 for the Diagnostic address (A2)
offset 110.

--