On Fri, Jan 22, 2021 at 04:03:23PM +0100, Fabrice Gasnier wrote:
> Currently, the STM32 LP Timer counter driver registers into both IIO and
> counter subsystems, which is redundant.
>
> Remove the IIO counter ABI and IIO registration from the STM32 LP Timer
> counter driver since it's been superseded by the Counter subsystem
> as discussed in [1].
>
> Keep only the counter subsystem related part.
> Move a part of the ABI documentation into a driver comment.
>
> This also removes a duplicate ABI warning
> $ scripts/get_abi.pl validate
> ...
> /sys/bus/iio/devices/iio:deviceX/in_count0_preset is defined 2 times:
> ./Documentation/ABI/testing/sysfs-bus-iio-timer-stm32:100
> ./Documentation/ABI/testing/sysfs-bus-iio-lptimer-stm32:0
>
> [1] https://lkml.org/lkml/2021/1/19/347
>
> Signed-off-by: Fabrice Gasnier <fabrice.gasnier@foss.st.com>

Acked-by: William Breathitt Gray <vilhelm.gray@gmail.com>

I'll also submit a patchset removing the IIO code from the 104-quad-8
driver and the rest of the IIO counter ABI documentation.

William Breathitt Gray